Loading...

    Submit Your PaperJournalsTrack Article StatusAPC
    AB Journals logo

    An international journal platform supporting research and innovation by making knowledge accessible to everyone, everywhere.

    15442 Ventura Blvd., Ste 201-1717, Sherman Oaks, California, 91403, USA.
    +1 (213) 371-4405
    WhatsApp: +1 (313) 787-3690
    XFacebookLinkedInInstagramYoutube

    Get Journal Updates

    Stay informed about newly published articles, latest issues, and announcements from your selected journals.

    Select Journals

    Receive updates by email. Unsubscribe at any time.

    For Authors

    • Submit Your Paper
    • Track Article Status
    • Editorial Process
    • Guidelines Hub
    • Manuscript Requirements
    • Submission Guidelines
    • Article Processing Charges
    • Pay APC
    • Open Access Policy
    • Waiver Policy

    Journal Subject

    • Management Sciences
    • Humanities & Social Sciences
    • Education
    • Sciences
    • Engineering

    About

    • About AB Journal
    • Policies & Ethics
    • Contact Us
    • Feedback
    • FAQs
    • Terms
    • Privacy Policy

    Resources

    • For Reviewers
    • For Editors
    • For Authors
    • Why Publish With Us

    Copyright © 2026 AB Journals. All rights reserved.

    Open Access
    AB Journals logo
    1. Home
    2. Search Results
    Submit Your PaperJournalsTrack Article StatusAPC

    Showing 5 results found

    Keywords
    ArticleCase Study
    Seasonal Dynamics of Coliform Contamination in Groundwater Associated with Onsite Sanitation: A Case Study of Peri-Urban Village Nawada, Patna, India.
    Aparna Anand, Sushil Kumar Singh, Shreyansh, Sweta Bharti, Prem Mishra
    July 31, 2026•DOI: 10.52589/AJENSR-JOPDJDHO•Volume 9 Issue 3•271 views
    Water is essential for the living world. Life cannot exist without water. For drinking purposes, water is obtained from many sources. Available sources of water on Earth are rivers, streams, groundwater, etc. In India, a major source of drinking water comes from groundwater through hand pumps, boring, or bore wells. Aquifers are the geographical formation of groundwater. An onsite sanitation system (OSS) is commonly used by the rural population of Bihar. Poorly designed or closely spaced OSS, like soak pits, lead to bacterial contamination of shallow aquifers, which poses a severe public health hazard in peri-urban and rural areas of Bihar. The present study investigates the microbial water quality of twenty different groundwater sources situated at variable lateral distances from the soak pit at Nawada village, Patna, Bihar, over three seasons, i.e., pre-monsoon (summer), monsoon, and post-monsoon (winter). By using the standard MPN technique, the most probable number of total coliforms per 100 ml of water sample was quantified. Based on the obtained result, it was found that groundwater was severely and widely contaminated with microbes during the monsoon season, due to a rise in water level, which accelerates the subterranean transport of bacteria. Most of the samples during the monsoon period show the presence of coliform, with the highest number of 1600. These results highlight the necessity of distance in sanitation-groundwater interaction, especially during the monsoon. Targeted intervention, development program, and public awareness campaign are recommended to reduce bacterial contamination in groundwater and improve the community health of Nawada. Read more
    Keywords:AquiferColiformGroundwaterMPNOSSSoak pit.
    ArticleResearch Article
    Integrated Geophysical and Hydrogeochemical Assessment of Dumpsite-Induced Soil and Groundwater Contamination in a Fractured Shale Aquifer System of Abakaliki, Southeastern Nigeria.
    Joseph Chidiebere Elem, Joseph I. Nwachukwu, Justin N. Okorondu, Iheoma E. Mbuka-Nwosu, Micheal A. Nwachukwu
    July 23, 2026•DOI: 10.52589/AJENSR-L26R13GT•Volume 9 Issue 3•300 views
    Rapid urbanization and indiscriminate waste disposal have intensified soil and groundwater contamination in many Nigerian cities. This study presents an integrated geophysical and hydrogeochemical assessment of subsurface contamination associated with major urban waste dumpsites within Abakaliki Metropolis, southeastern Nigeria, underlain predominantly by fractured and weathered shale of the Asu River Group. Vertical Electrical Sounding (VES) employing the Schlumberger electrode configuration and two-dimensional (2-D) electrical resistivity imaging using the dipole–dipole array were conducted at three major dumpsites: Rice Mill, Umuoghara, and Mechanic Village. The acquired resistivity data were processed using Advanced Geosciences Incorporated (AGI) inversion software and Res2Dinv software to delineate subsurface lithology, fracture systems, aquifer characteristics, and leachate-contaminated zones. The geophysical results revealed low resistivity values ranging from 7–19 Ωm within the topsoil and weathered shale units, indicating highly conductive zones associated with moisture accumulation and leachate infiltration. Moderately to highly resistive layers (118–24,201 Ωm), interpreted as sandstone lenses, silty sand, and siltstone units, were identified at intermediate depths, while deep conductive zones with very low resistivity values (0.18–3.04 Ωm) were interpreted as fractured and saturated shale aquifers vulnerable to contaminant migration. To validate the geophysical interpretation, physicochemical and heavy metal analyses were carried out on soil and surface water samples collected around the investigated dumpsites. Elevated concentrations of heavy metals, including Pb, Cd, Hg, Cr, and Ni, were detected in several samples, with some values exceeding World Health Organization (WHO) permissible limits. The integration of geophysical, physicochemical, and geochemical data confirms the occurrence of leachate-induced subsurface contamination and demonstrates the vulnerability of fracture-controlled aquifer systems within the study area. The study demonstrates the effectiveness of integrating electrical resistivity techniques with hydrogeochemical analyses for environmental assessment and groundwater vulnerability studies in shale-dominated terrains affected by uncontrolled waste disposal activities. Read more
    Keywords:2-D Electrical Resistivity Imaging; Electrical Resistivity; Fractured Shale Aquifer; Groundwater Vulnerability; Heavy Metal Contamination; Hydrogeochemistry; Vertical Electrical Sounding (VES).
    ArticleResearch Article
    Integrated Assessment of Aquifer Contamination Risk Using GOD, GODL, and GLSI Models in Southern Okigwe, Southeastern Nigeria.
    Anyanwu Jude Maduabuchi, Daniel Nnaemeka Obiora, Desmond Okechukwu Ugbor, Johnson Cletus Ibuot, James Sampson Obinna
    December 2, 2025•DOI: 10.52589/AJENSR-FSX0G6Y1•Volume 8 Issue 3•524 views
    This study assesses aquifer contamination across fifty VES locations in Okigwe South, Southeastern Nigeria, using the GOD, GODL, and GLSI models. The GOD Index classifies vulnerability based on geological setting, overlying soil, and depth to groundwater. Results show that EHUME falls within the extreme vulnerability category, while locations like UMUOKE and UMUDIMIRE are highly vulnerable, requiring urgent protective measures. Moderate to low vulnerability was observed in several other locations, indicating varying degrees of natural protection. The GODL Index, an extension of the GOD model incorporating resistivity, depth, longitudinal conductance, and location, provided a more detailed classification. Sites such as UMUAWUCHI II and UMUARIAM II recorded high GODL values, suggesting thick, resistive formations, while areas like IKPEREJERE II showed low values, reflecting more conductive and potentially vulnerable subsurface conditions. Comparative analysis shows that GODL values were consistently higher than GOD values, emphasizing the role of human activity and land use in increasing groundwater contamination risk. The GLSI model, based on resistivity and layer thickness, further refined the classification. Locations such as UMUARIAM and AMANZE demonstrated strong natural protection (low vulnerability), while UMUOKE and UMUAWUCHI II were flagged as highly vulnerable zones due to weak protective layers. The integration of these models offers a robust approach for identifying contamination risks and guiding groundwater protection strategies. It highlights the need for targeted monitoring, land-use regulation, and sustainable groundwater development in vulnerable areas. Read more
    Keywords:Aquifer contaminationGOD IndexGODL IndexGLSI modelGroundwater protection.
    Article
    Estimation of Groundwater Potential and Aquifer Protective Capacity Within Old Ikenga Hotel, Nsukka, Enugu State, Nigeria.
    Olisah Nzemeka C., Obiekezie Theresa N.
    July 15, 2024•DOI: 10.52589/AJENSR-NO8MPITK•Volume 7 Issue 3•1,572 views
    A geophysical survey using electrical resistivity method was conducted around Old Ikenga Hotel, Nsukka in Enugu State, Nigeria to investigate the groundwater potential and aquifer protective capacity of the area. The project area lies within latitudes 6°50'4.0''N - 6°57'52.0"N and longitudes 7°21'6.3"E - 7°28'12.0"E, and covers an area of about 89.6 km2. Vertical Electrical Soundings (VES) were carried out with a digital read out resistivity meter (ABEM SAS 1000). The VES points were marked at 25 m and 75 m along a 100 m line. A total of eight soundings were carried out in the area. The VES data collected were interpreted using INTERPEX software and the results presented in terms of resistivity, thickness, depth and lithology. The lithology was inferred by correlating the result to the lithology log of the borehole drilled in the hotel and the geology of the study area. The VES result shows lithologic layers varying from 4 to 5. Aquiferous sand and Aquiferous sandy shale constitute the aquifer units in the area at depth of 30.26 m to 188.20 m, with their thickness ranging from 30 m to 74 m as shown by their isopach map. The aquifer protective capacity was determined by calculating for longitudinal conductance and matching the values to known standards. The calculated longitudinal conductance varies from 0.0409 to 3.1235 mhos. The interpreted VES results reveal poor, moderate, good and very good aquifer protective capacities of the overburden layers. Read more
    Keywords:AquiferLongitudinal conductanceBoreholeGeoelectric sectionVertical Electrical SoundingResistivityNsukkaOld IkengaAquifer protective capacity.
    Article
    Multi-Criteria Analysis Method for Aquifer Vulnerability Investigation Using Godt Method at Idi-Ayunre, Ibadan, Southwestern Nigeria
    Olukayode O.O., Bayewu O.O., Adebisi N.O., Mosuro G.O., Ariyo S.O., Orimogunje O.B.
    August 1, 2023•DOI: 10.52589/AJENSR-7DF7DJ7O•Volume 6 Issue 2•1,460 views
    Geophysical investigation involving Vertical Electrical Sounding (VES) Schlumberger array was carried out across Idi-Ayunre, Ibadan, a typical basement complex area having a rock composition of migmatite-gneiss, quartzite, and biotite-hornblende. A total of forty (40) vertical electrical sounding data were acquired with maximum current electrode separation of 100m using resistivity meter and its accessories. The aim of the study was to evaluate the aquifer vulnerability of the study area to contamination. The VES results were both qualitatively and quantitatively interpreted using partial curve matching and were further subjected to computer iteration using WINRESIST. The longitudinal conductance, thickness of layer overlying aquifer and hydraulic conductivity were generated and synthesized to produce the vulnerability map. A GODT multi-criteria model which is an acronym of Groundwater occurrence, Overburden thickness, Depth and Topography developed from the hydrogeologic parameters were evaluated alongside the longitudinal conductance values to determine the aquifer vulnerability of the area and to classify the study area accordingly. The curve type obtained are H and HA. The interpretation revealed three to four geoelectric layers: the topsoil (18.9-178.9Ωm), clayey (9.0-70.6Ωm), fractured basement (31.9-43.1Ωm) and fresh basement (1131-2916Ωm). The longitudinal unit conductance ranges from 0.032-0.93mhos. And from the GODT model derivations, the study area shows 92.5% of high vulnerability rating, 2.5% of low-moderate and 5% of moderate rating; areas with high rating are prone to contamination than areas with low-moderate and moderate rating. Hence, zones of high vulnerability may be not be encouraged for groundwater exploitation and, if need be, constant water quality assessment should be carried out before consumption. Read more
    Keywords:AquiferVulnerabilityElectrical ResistivityLongitudinal ConductanceOverlying lithologyDepth and Topography.