Loading...

    Submit Your PaperJournalsTrack Article StatusAPC
    AB Journals logo

    An international journal platform supporting research and innovation by making knowledge accessible to everyone, everywhere.

    15442 Ventura Blvd., Ste 201-1717, Sherman Oaks, California, 91403, USA.
    +1 (213) 371-4405
    WhatsApp: +1 (313) 787-3690
    XFacebookLinkedInInstagramYoutube

    Get Journal Updates

    Stay informed about newly published articles, latest issues, and announcements from your selected journals.

    Select Journals

    Receive updates by email. Unsubscribe at any time.

    For Authors

    • Submit Your Paper
    • Track Article Status
    • Editorial Process
    • Guidelines Hub
    • Manuscript Requirements
    • Submission Guidelines
    • Article Processing Charges
    • Pay APC
    • Open Access Policy
    • Waiver Policy

    Journal Subject

    • Management Sciences
    • Humanities & Social Sciences
    • Education
    • Sciences
    • Engineering

    About

    • About AB Journal
    • Policies & Ethics
    • Contact Us
    • Feedback
    • FAQs
    • Terms
    • Privacy Policy

    Resources

    • For Reviewers
    • For Editors
    • For Authors
    • Why Publish With Us

    Copyright © 2026 AB Journals. All rights reserved.

    Open Access
    AB Journals logo
    1. Home
    2. Search Results
    Submit Your PaperJournalsTrack Article StatusAPC

    Showing 6 results found

    Keywords
    ArticleResearch Article
    Chemical Characterization of Fresh and Used ATF of Gearbox Via FTIR Spectroscopy.
    Tijjani Abubakar, Nafisa Garba, Bashir K. Ibrahim
    October 23, 2025•DOI: 10.52589/IRME-7F0NH2QV•Volume 5 Issue 2•582 views
    Automatic transmission (AT) systems are widely recognized for enhancing vehicle safety, comfort, reliability, and overall driving performance. During regular operation, the automatic transmission fluid (ATF) within the gearbox undergoes various physical and chemical changes. Some constituents of ATF—especially in its used state—pose potential risks to public health and the environment. This study aims to collect ATF samples from the gearbox of a bus engine and analyze them using Fourier-transform infrared (FTIR) spectroscopy. FTIR was utilized to characterize the chemical composition of both fresh and used ATF samples. Absorption bands in the 1704–1603 cm⁻¹ region were attributed to carbonyl functional groups, while peaks at 869, 813, and 1603 cm⁻¹ corresponded to newly formed aromatic hydrocarbons, including polycyclic aromatic hydrocarbons. The FTIR spectra of the used ATF revealed the presence of alcohols, aldehydes, and ketones, suggesting significant chemical and biological degradation. Key words: Automatic transmission fluid (ATF), Gearbox, FTIR. Read more
    Keywords:Automatic transmission fluid (ATF)GearboxFTIR.
    ArticleResearch Article
    Conjugate Impacts of Linear Variable Thermal Conductivity and Thermal Radiation on Nonlinear Electrically Conducting Fluid.
    Zayyanu Sahabi Yabo, Abdullahi Hussaini, Isah Bala Yabo
    October 29, 2024•DOI: 10.52589/AJMSS-EBCFFU7A•Volume 7 Issue 4•921 views
    This study investigates the conjugate impacts of variable thermal conductivity and thermal radiation on nonlinear heat conducting fluid moving vertically through parallel channel. The dimensional governing equations were reduced to dimensionless partial differential equations and consequently transformed to ordinary differential equations. The resulting ordinary differential equations were solved using homotopy perturbation method. The study aimed at discovering the possible effects of thermal radiation parameter, thermal conductivity parameter, temperature difference parameter and Magnetic parameter through the help of line graphs. It was found that, Velocity and temperature distributions were increasing functions of , while Velocity and temperature distributions are decreasing functions of Thermal conductivity parameter Read more
    Keywords:Thermal conductivityHomotopy perturbationthermal conductivityelectrically conducting fluidMHD.
    ArticleResearch Article
    Mixed Convection Flow of a Viscous Dissipative and Heat Generating/Absorbing Fluid Through a Slit Microchannel.
    Godwin Ojemeri, A. S. Ibrahim, I. O. Onwubuya
    October 23, 2024•DOI: 10.52589/AJMSS-LA7BTCRZ•Volume 7 Issue 4•884 views
    This paper is aimed at investigating the consequences of viscous dissipation and super-hydrophobicity on a magnetized mixed convection flow of an electrically conducting fluid across an up facing microchannel influenced by a transverse magnetic field. The plates were alternatively heated and incorporated with heat source/sink effect. The modeled governing equations have been obtained using a semi-analytical (regular perturbation) method. Various line graphs have been plotted to demonstrate the behavior of key parameter dictating the flow. It is found out that the thermal gradient and fluid velocity are significantly enhanced for mounting values of mixed convection , Brickman number , Darcy porous number and heat source parameters in the superhydrophobic microchannel for constant pressure gradient . On the other hand, the velocity deteriorates for increasing levels of magnetic field and heat sink factors. Further, the comparison of this present analysis with previously published literature for limiting cases when and showcased an excellent concurrence, thereby confirming the accuracy and validity of this present investigation. The findings from this research will find relevance in engineering, technological and industrial processes such as for solar collectors, nuclear reactors cooled during emergency shutdown, Nuclear power plants, gas turbines and the various propulsion devices for aircraft, missiles, satellites and space vehicles. Read more
    Keywords:Viscous dissipative fluidHeat source/sinkMagnetohydrodynamics (MHD)Superhydrophobic surface (SHS)Slit Microchannel.
    Article
    Entropy Generation For Non-Newtonian Fluid With Constant Viscosity
    Obi Boniface Inalu
    April 3, 2024•DOI: 10.52589/AJMSS-3FOWTMHB•Volume 7 Issue 2•1,312 views
    In this research, entropy generation for non-Newtonian fluid flow with constant viscosity is considered. The governing nonlinear equations of motion are solved analytically with regular perturbation techniques. Third grade fluid is employed to account for the non-Newtonian influence. The influence of some physical parameters involved in the analysis is studied. Results show that the parameter has the tendency of increasing the velocity of the fluid flow as well as the temperature of the cylindrical pipe. It is observed that as the Brinkman parameter increases, the cylindrical wall temperature is enhanced. Entropy generation number for both heat transfer and fluid friction for various values of and is examined. Results indicate that increase in these parameters increases the temperature of the cylinder, thereby increasing the entropy generation number. Read more
    Keywords:EntropyNon-NewtonianFluidViscosity.
    Article
    Solution of One-dimensional Partial Differential Equation with Higher-Order Derivative by Double Laplace Transform Method
    Anongo D.O., Awari Y.S.
    August 7, 2021•DOI: 10.52589/AJMSS-1OHGJPNR•Volume 4 Issue 3•1,964 views
    Many problems in natural and engineering sciences such as heat transfer, elasticity, quantum mechanics, water flow, and others are modelled mathematically by partial differential equations. Some of these problems may be linear, nonlinear, homogeneous, non-homogeneous, and order greater or equal one. Finding the theoretical solution to these problems with less cumbersome techniques is an active area of research in the aforementioned field. In this research paper, we have developed a new application of the double Laplace transform method to solve homogeneous and non-homogeneous linear partial differential equations (pdes) with higher-order derivatives (i.e order n where n≥2) in science and engineering. We discussed a brief theory of double Laplace transforms that helped in its application. The main advantage of our method is the reduction of computational effort in finding solution to pdes. Another major benefit of our method is solving problems in the form of (21) directly by transforming to an algebraic equation where the inverse double Laplace transform is implemented for analytical solution, unlike other integral transform methods that would first transform to a system of ODEs before they are solved, is it also very effective in solving linear high-order partial differential equations and yield fast convergence. We present a well-simplified solution for easier comprehension by upcoming researchers. Read more
    Keywords:Double-Laplace TranformPartial Differential EquationsBoundary Value ProblemsExponential OrderFluid Dynamics.
    Article
    Exposure to Occupational-related Blood and Fluids Infections, Accidental Injuries and Precaution Practices among Healthcare Workers in a Tertiary Hospital in South-West, Nigeria
    Adetoun A. Oyekunle, Olanrewaju A. Idowu, Temidayo O. Awvioro, Oluwasayo B. Ogunlade (Ph.D)
    November 18, 2021•DOI: 10.52589/AJHNM-ZUHMCMEB•Volume 4 Issue 6•2,314 views
    Background and Aim: Healthcare workers are at risk of infections from blood-borne pathogens due to percutaneous injuries from sharps, mucous membrane and skin exposures to contaminated blood and bodily fluids. The study, therefore, investigated exposure to occupational-related blood and fluids infections, accidental injuries and precaution practices among health care workers in a tertiary hospital in South-West, Nigeria. Methods: The study utilised a cross-sectional research design requiring a structured questionnaire to elicit data from medical doctors, nurses and laboratory scientists/technologists. Through the convenience sampling technique, 266 respondents were selected for the study. Non-parametric descriptive statistics were used to analyse the data with the level of significance of the chi-square test put at 5%. Results: The overwhelming majority (76%) of the health care workers at the hospital are of the female gender. The study found that the majority of the respondents (92%) were trained on infection control in the course of their career while virtually all of them (98%) had never contracted an occupational-related infection. Recapping of used needles accounted for 24.4% of activity that predisposed the workers to accidental injuries. Also, there was a significant association between the recapping of needles and the occurrence of accidental injuries (P.V. = 0.000). Meanwhile, the incidence of unreported injuries stood at 70.3% as all the reasons given were significant (P.V. = 0.000) using a one-sample chi-square test. Conclusion: It has been established that prevention practices like training in infection control, adherence to clear work procedures and guidelines, post-exposure prophylaxis and use of personal protective equipment were associated with contraction of occupational-related infections. Moreover, while recapping of used needles was a usual practice in the hospital, it was, however, associated with cases of accidental injuries among most health care workers. Unfortunately, most cases of injuries were unreported due to certain significant reasons. Read more
    Keywords:Occupational InfectionBlood and Body FluidsPost-Exposure ProphylaxisRecappingUn-reported injuries.