Loading...

    Submit Your PaperJournalsTrack Article StatusAPC
    AB Journals logo

    An international journal platform supporting research and innovation by making knowledge accessible to everyone, everywhere.

    15442 Ventura Blvd., Ste 201-1717, Sherman Oaks, California, 91403, USA.
    +1 (213) 371-4405
    WhatsApp: +1 (313) 787-3690
    XFacebookLinkedInInstagramYoutube

    Get Journal Updates

    Stay informed about newly published articles, latest issues, and announcements from your selected journals.

    Select Journals

    Receive updates by email. Unsubscribe at any time.

    For Authors

    • Submit Your Paper
    • Track Article Status
    • Editorial Process
    • Guidelines Hub
    • Manuscript Requirements
    • Submission Guidelines
    • Article Processing Charges
    • Pay APC
    • Open Access Policy
    • Waiver Policy

    Journal Subject

    • Management Sciences
    • Humanities & Social Sciences
    • Education
    • Sciences
    • Engineering

    About

    • About AB Journal
    • Policies & Ethics
    • Contact Us
    • Feedback
    • FAQs
    • Terms
    • Privacy Policy

    Resources

    • For Reviewers
    • For Editors
    • For Authors
    • Why Publish With Us

    Copyright © 2026 AB Journals. All rights reserved.

    Open Access
    AB Journals logo
    1. Home
    2. Search Results
    Submit Your PaperJournalsTrack Article StatusAPC

    Showing 3 results found

    Keywords
    ArticleResearch Article
    Integrated Geophysical and Hydrogeochemical Assessment of Dumpsite-Induced Soil and Groundwater Contamination in a Fractured Shale Aquifer System of Abakaliki, Southeastern Nigeria.
    Joseph Chidiebere Elem, Joseph I. Nwachukwu, Justin N. Okorondu, Iheoma E. Mbuka-Nwosu, Micheal A. Nwachukwu
    July 23, 2026•DOI: 10.52589/AJENSR-L26R13GT•Volume 9 Issue 3•305 views
    Rapid urbanization and indiscriminate waste disposal have intensified soil and groundwater contamination in many Nigerian cities. This study presents an integrated geophysical and hydrogeochemical assessment of subsurface contamination associated with major urban waste dumpsites within Abakaliki Metropolis, southeastern Nigeria, underlain predominantly by fractured and weathered shale of the Asu River Group. Vertical Electrical Sounding (VES) employing the Schlumberger electrode configuration and two-dimensional (2-D) electrical resistivity imaging using the dipole–dipole array were conducted at three major dumpsites: Rice Mill, Umuoghara, and Mechanic Village. The acquired resistivity data were processed using Advanced Geosciences Incorporated (AGI) inversion software and Res2Dinv software to delineate subsurface lithology, fracture systems, aquifer characteristics, and leachate-contaminated zones. The geophysical results revealed low resistivity values ranging from 7–19 Ωm within the topsoil and weathered shale units, indicating highly conductive zones associated with moisture accumulation and leachate infiltration. Moderately to highly resistive layers (118–24,201 Ωm), interpreted as sandstone lenses, silty sand, and siltstone units, were identified at intermediate depths, while deep conductive zones with very low resistivity values (0.18–3.04 Ωm) were interpreted as fractured and saturated shale aquifers vulnerable to contaminant migration. To validate the geophysical interpretation, physicochemical and heavy metal analyses were carried out on soil and surface water samples collected around the investigated dumpsites. Elevated concentrations of heavy metals, including Pb, Cd, Hg, Cr, and Ni, were detected in several samples, with some values exceeding World Health Organization (WHO) permissible limits. The integration of geophysical, physicochemical, and geochemical data confirms the occurrence of leachate-induced subsurface contamination and demonstrates the vulnerability of fracture-controlled aquifer systems within the study area. The study demonstrates the effectiveness of integrating electrical resistivity techniques with hydrogeochemical analyses for environmental assessment and groundwater vulnerability studies in shale-dominated terrains affected by uncontrolled waste disposal activities. Read more
    Keywords:2-D Electrical Resistivity Imaging; Electrical Resistivity; Fractured Shale Aquifer; Groundwater Vulnerability; Heavy Metal Contamination; Hydrogeochemistry; Vertical Electrical Sounding (VES).
    Article
    Estimation of Groundwater Potential and Aquifer Protective Capacity Within Old Ikenga Hotel, Nsukka, Enugu State, Nigeria.
    Olisah Nzemeka C., Obiekezie Theresa N.
    July 15, 2024•DOI: 10.52589/AJENSR-NO8MPITK•Volume 7 Issue 3•1,578 views
    A geophysical survey using electrical resistivity method was conducted around Old Ikenga Hotel, Nsukka in Enugu State, Nigeria to investigate the groundwater potential and aquifer protective capacity of the area. The project area lies within latitudes 6°50'4.0''N - 6°57'52.0"N and longitudes 7°21'6.3"E - 7°28'12.0"E, and covers an area of about 89.6 km2. Vertical Electrical Soundings (VES) were carried out with a digital read out resistivity meter (ABEM SAS 1000). The VES points were marked at 25 m and 75 m along a 100 m line. A total of eight soundings were carried out in the area. The VES data collected were interpreted using INTERPEX software and the results presented in terms of resistivity, thickness, depth and lithology. The lithology was inferred by correlating the result to the lithology log of the borehole drilled in the hotel and the geology of the study area. The VES result shows lithologic layers varying from 4 to 5. Aquiferous sand and Aquiferous sandy shale constitute the aquifer units in the area at depth of 30.26 m to 188.20 m, with their thickness ranging from 30 m to 74 m as shown by their isopach map. The aquifer protective capacity was determined by calculating for longitudinal conductance and matching the values to known standards. The calculated longitudinal conductance varies from 0.0409 to 3.1235 mhos. The interpreted VES results reveal poor, moderate, good and very good aquifer protective capacities of the overburden layers. Read more
    Keywords:AquiferLongitudinal conductanceBoreholeGeoelectric sectionVertical Electrical SoundingResistivityNsukkaOld IkengaAquifer protective capacity.
    Article
    Application of Geophysical Technique in Delineation of Marble Deposit in Ikpeshi, Edo, Nigeria
    Sanni Eshovo Blessing, Mohammed Musa Musa, Momoh Shaka Dalanmi, Oyemi Osikwemhe Gregory
    October 10, 2023•DOI: 10.52589/AJENSR-M42VSLYZ•Volume 6 Issue 3•1,765 views
    The increasing demand for mineral substances and the need to maintain the current consumption pattern require constant research for new deposits or studies to expand exploration reserves. A geophysical technique was employed in the delineation of this mineral deposit. The results obtained in each VES have three geo-electric layers, which comprise clay/clayey-sand (81.8 – 155.7 Ωm), Sand (101.8 – 380.4 Ωm) and marble (1019 – 4419 Ωm) horizon units. The geologic section was deduced from borehole log data acquired within the study area. All the surveyed locations show traces of the existence of marble deposits in the area. The study revealed occurrences of marble deposits in the study area, which will be of economic importance if exploited. The reserve tonnage was calculated to be about 1.69 x 10⁶ tons. This estimate signifies that there is a fair reserve of marble within the study portion of the location. Read more
    Keywords:MarbleResistivityVertical Electrical Sounding (VES)Reserve Toonageand reserve volume.