Loading...

    Submit Your PaperJournalsTrack Article StatusAPC
    AB Journals logo

    An international journal platform supporting research and innovation by making knowledge accessible to everyone, everywhere.

    15442 Ventura Blvd., Ste 201-1717, Sherman Oaks, California, 91403, USA.
    +1 (213) 371-4405
    WhatsApp: +1 (313) 787-3690
    XFacebookLinkedInInstagramYoutube

    Get Journal Updates

    Stay informed about newly published articles, latest issues, and announcements from your selected journals.

    Select Journals

    Receive updates by email. Unsubscribe at any time.

    For Authors

    • Submit Your Paper
    • Track Article Status
    • Editorial Process
    • Guidelines Hub
    • Manuscript Requirements
    • Submission Guidelines
    • Article Processing Charges
    • Pay APC
    • Open Access Policy
    • Waiver Policy

    Journal Subject

    • Management Sciences
    • Humanities & Social Sciences
    • Education
    • Sciences
    • Engineering

    About

    • About AB Journal
    • Policies & Ethics
    • Contact Us
    • Feedback
    • FAQs
    • Terms
    • Privacy Policy

    Resources

    • For Reviewers
    • For Editors
    • For Authors
    • Why Publish With Us

    Copyright © 2026 AB Journals. All rights reserved.

    Open Access
    AB Journals logo
    1. Home
    2. Search Results
    Submit Your PaperJournalsTrack Article StatusAPC

    Showing 3 results found

    Keywords
    Article
    Effect of Voltage variation on the Geotechnical Properties and Removal Efficiency of heavy metal contaminants from contaminated soil using Electrokinetic Remediation Technique
    Seidu Tijani, Rotimi Juwon Abdulazeez
    September 10, 2024•DOI: 10.52589/IJMCE-NUOVN7UC•Volume 7 Issue 2•1,198 views
    A lot of research work has shown that despite the effectiveness of the electrokinetic remediation technology in decontaminating heavy metal contaminated soils, more work is still required to fully understand the role of voltage in the remediation process. There is need to establish the optimum voltage that would best remove heavy metals from such contaminated soil and its attendant effect on the geotechnical properties of the remediated soil. Effect of voltage variation on the removal efficiency of lead, copper and the geotechnical properties of remediated heavy metal contaminated soil using electrokinetic remediation technique was investigated in this research. The contaminated soil was remediated by applying direct current (DC) to the remediation setup at 0.5V/cm, 1.0V/cm, 1.5V/cm and 2.0V/cm. The concentration of the heavy metals after remediation were determined using the Oxford Instrument Analyzer to evaluate removal efficiency, geotechnical properties tests were also conducted on the soil specimens at each phase of remediation. The results showed that the lead removal efficiency was highest at 2.0V/cm (86%) with the shortest remediation time of 5days and lowest at 0.5V/cm (39%) at 9days. 52% of copper was removed at 2.0V/cm in 5days and 29% at 0.5V/cm after 9days of remediation. At 1.0V/cm, the lead and copper removal efficiency are 75% and 40% respectively. There was no significant change in the Specific Gravity of all the soil samples with the test results lying between 2.0 and 2.2. The soil is generally silty fine sand with not less than 40% passing the sieve no.200 (75micron). 45% passed through sieve 75micron for unremediated soil and slightly reduced to 40%, 40.4% and 40.2% for 30V, 45V and 60V respectively. The soil is non-plastic with the liquid limit of between 25.8% and 29.5% belonging to the A-4 group of soil. The maximum dry density improved across all the three compactive efforts, from 1.8390g/cm3 to 1.8480g/cm3 with WAS compactive effort and from 1.8000g/cm3 to 1.8320g/cm3 with BSL method with an average optimum moisture content of 10%. The CBR values increases with increase in voltage applied. The unsoaked CBR values averagely increased with 31%, 18% and 7% for BSH, WAS and BSL compactive efforts respectively. The durability index with resistances of 89% and 90% to loss in strength was recorded at 1.0V/cm and 1.5V/cm respectively, this, when compared to the resistance to loss in strength of 71% in unremediated soil has respectively 25.3% and 26.8% durability advantages. There was also a consistent increase in the UCS values, from 381kN/m2 to 474kN/m2 and from 351kN/m2 to 447kN/m2 when WAS and BSL methods of compaction were used. Generally, there was improvement in the geotechnical properties of the remediated soil. These improvements are maximum at 1.0V/cm and 1.5V/cm with little or no further improvement at 2.0V/cm. It is recommended that 1.0V and 1.5V are suitable for remediation purpose since it requires low energy consumption. Read more
    Keywords:Electrokinetic remediationremoval efficiencyvoltagegeotechnical propertiesheavy metal.
    Article
    Power Failure and Entrepreneurial Behaviour in Akwa Ibom State
    Christabel D. Brownson
    April 14, 2023•DOI: 10.52589/BJMMS-VU43UOQC•Volume 6 Issue 2•1,507 views
    Reliable electricity supply is a vital tool for successful operations of entrepreneurial businesses. However, unreliable power supply is one of the greatest problems confronting business activities in Nigeria. Although several research works have been done on the subject, none of such studies have examined power failure and entrepreneurial behaviour of entrepreneurs in Akwa Ibom State. It is therefore the aim of this study to investigate power failure and entrepreneurial behaviour of entrepreneurs in Uyo metropolis of Akwa Ibom State. Using a descriptive design, 120 entrepreneurs were examined purposively for the study. Findings revealed that frequent power failure in terms of power outage adversely affect the operations of the businesses in the state with high and low voltage damaging the machineries used by the entrepreneurs to operate their businesses leading to constant repairs, replacement, loss of patronage and impeding the growth of their businesses. Hence, it is recommended that the government should do more to arrest the issue of unreliable energy supply in the state to boost businesses and reduce high cost of operation due to the usage of personally sourced alternative power supply. Read more
    Keywords:Power FailurePower OutageLow VoltageHigh VoltageEntrepreneurial behaviourAkwa Ibom State.
    Article
    Voltage and Frequency Control for Hybrid Stand-Alone Power Systems For Isolated Communities
    Adebayo Adeniyi D., Christian Adi
    November 14, 2021•DOI: 10.52589/AJSTE-QAXNEWUM•Volume 1 Issue 1•1,425 views
    This paper proposes a control and overall coordination of a hybrid stand-alone power system. The system may comprise a wind turbine, fuel cell, electrolyzer, battery storage, diesel generator and a set of loads. The overall control planning of the hybrid system is based on a two-level structure. The top-level is the energy management and power regulation system. Depending on wind and load conditions, this system generates reference dynamic operating points to low-level individual sub-systems. The energy management and power regulation system also controls the load scheduling operation during unfavourable wind conditions with inadequate energy storage in order to avoid a system black-out. Based on the reference dynamic operating points of the individual sub-systems, the local controllers control the wind turbine, fuel cell, electrolyzer and battery storage units. The proposed control system is implemented in MATLAB Simpower software and tested for various wind and load conditions. Results are presented and elucidated. Read more
    Keywords:VoltageFrequencyVoltage and Frequency ControlHybrid Stand Alone Power System and Isolated Communities.