Multi-Criteria Analysis Method for Aquifer Vulnerability Investigation Using Godt Method at Idi-Ayunre, Ibadan, Southwestern Nigeria

Publication Date: 01/08/2023

DOI: 10.52589/AJENSR-7DF7DJ7O


Author(s): Olukayode O.O., Bayewu O.O., Adebisi N.O., Mosuro G.O., Ariyo S.O., Orimogunje O.B..

Volume/Issue: Volume 6 , Issue 2 (2023)



Abstract:

Geophysical investigation involving Vertical Electrical Sounding (VES) Schlumberger array was carried out across Idi-Ayunre, Ibadan, a typical basement complex area having a rock composition of migmatite-gneiss, quartzite, and biotite-hornblende. A total of forty (40) vertical electrical sounding data were acquired with maximum current electrode separation of 100m using resistivity meter and its accessories. The aim of the study was to evaluate the aquifer vulnerability of the study area to contamination. The VES results were both qualitatively and quantitatively interpreted using partial curve matching and were further subjected to computer iteration using WINRESIST. The longitudinal conductance, thickness of layer overlying aquifer and hydraulic conductivity were generated and synthesized to produce the vulnerability map. A GODT multi-criteria model which is an acronym of Groundwater occurrence, Overburden thickness, Depth and Topography developed from the hydrogeologic parameters were evaluated alongside the longitudinal conductance values to determine the aquifer vulnerability of the area and to classify the study area accordingly. The curve type obtained are H and HA. The interpretation revealed three to four geoelectric layers: the topsoil (18.9-178.9Ωm), clayey (9.0-70.6Ωm), fractured basement (31.9-43.1Ωm) and fresh basement (1131-2916Ωm). The longitudinal unit conductance ranges from 0.032-0.93mhos. And from the GODT model derivations, the study area shows 92.5% of high vulnerability rating, 2.5% of low-moderate and 5% of moderate rating; areas with high rating are prone to contamination than areas with low-moderate and moderate rating. Hence, zones of high vulnerability may be not be encouraged for groundwater exploitation and, if need be, constant water quality assessment should be carried out before consumption.


Keywords:

Aquifer, Vulnerability, Electrical Resistivity, Longitudinal Conductance, Overlying lithology, Depth and Topography.


No. of Downloads: 0

View: 198




This article is published under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
CC BY-NC-ND 4.0